507 lines
14 KiB
Lua
Executable File
507 lines
14 KiB
Lua
Executable File
#!/usr/bin/env lua
|
|
|
|
--[[
|
|
|
|
fsync.lua - synchronize /etc/config/flukso settings with the sensor board
|
|
via the spid ctrl fifos
|
|
|
|
Copyright (C) 2011 Bart Van Der Meerssche <bart.vandermeerssche@flukso.net>
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
]]--
|
|
|
|
|
|
local dbg = require 'dbg'
|
|
local nixio = require 'nixio'
|
|
nixio.fs = require 'nixio.fs'
|
|
local uci = require 'luci.model.uci'.cursor()
|
|
local luci = require 'luci'
|
|
luci.json = require 'luci.json'
|
|
local httpclient = require 'luci.httpclient'
|
|
|
|
|
|
local HW_CHECK_OVERRIDE = (arg[1] == '-f')
|
|
|
|
local CTRL_PATH = '/var/run/spid/ctrl'
|
|
local CTRL_PATH_IN = CTRL_PATH .. '/in'
|
|
local CTRL_PATH_OUT = CTRL_PATH .. '/out'
|
|
|
|
local O_RDWR_NONBLOCK = nixio.open_flags('rdwr', 'nonblock')
|
|
local O_RDWR_CREAT = nixio.open_flags('rdwr', 'creat')
|
|
local POLLIN = nixio.poll_flags('in')
|
|
local POLL_TIMEOUT_MS = 1000
|
|
local MAX_TRIES = 5
|
|
|
|
-- parse and load /etc/config/flukso
|
|
local flukso = uci:get_all('flukso')
|
|
|
|
local MAX_SENSORS = tonumber(flukso.main.max_sensors)
|
|
local MAX_ANALOG_SENSORS = tonumber(flukso.main.max_analog_sensors)
|
|
local RESET_COUNTERS = (flukso.main.reset_counters == '1')
|
|
local SYNC_TO_SERVER = (flukso.daemon.enable_wan_branch == '1')
|
|
|
|
local METERCONST_FACTOR = 0.449
|
|
|
|
-- sensor board commands
|
|
local GET_HW_VERSION = 'gh'
|
|
local GET_HW_VERSION_R = '^gh%s+(%d+)%s+(%d+)$'
|
|
local SET_ENABLE = 'se %d %d'
|
|
local SET_PHY_TO_LOG = 'sp' -- with [1..MAX_SENSORS] arguments
|
|
local SET_METERCONST = 'sm %d %d'
|
|
local SET_COUNTER = 'sc %d %d'
|
|
local COMMIT = 'ct'
|
|
|
|
-- LAN settings
|
|
local API_PATH = '/www/sensor/'
|
|
local CGI_SCRIPT = '/usr/bin/restful'
|
|
local AVAHI_PATH = '/etc/avahi/services/flukso.service'
|
|
|
|
-- WAN settings
|
|
local WAN_BASE_URL = flukso.daemon.wan_base_url .. 'sensor/'
|
|
local WAN_KEY = '0123456789abcdef0123456789abcdef'
|
|
uci:foreach('system', 'system', function(x) WAN_KEY = x.key end) -- quirky but it works
|
|
|
|
-- https header helpers
|
|
local FLUKSO_VERSION = '000'
|
|
uci:foreach('system', 'system', function(x) FLUKSO_VERSION = x.version end)
|
|
|
|
local USER_AGENT = 'Fluksometer v' .. FLUKSO_VERSION
|
|
local CACERT = flukso.daemon.cacert
|
|
|
|
|
|
--- Convert from Lua-style to c-style index.
|
|
-- @param index Lua-style index startng at 1
|
|
-- @return C-style index starting at 0
|
|
local function toc(index)
|
|
return index - 1
|
|
end
|
|
|
|
--- Log exit status to syslog first, then exit.
|
|
-- @param code exit status code
|
|
-- @return none
|
|
local function exit(code)
|
|
local level
|
|
|
|
if code == 0 then
|
|
level = 'info'
|
|
else
|
|
level = 'err'
|
|
end
|
|
|
|
nixio.syslog(level, string.format('fsync exit status: %d', code))
|
|
os.exit(code)
|
|
end
|
|
|
|
--- Create a pair of file descriptors [fd] to the spid control fifo's.
|
|
-- @return ctrl object containing the fd's, a line-based iterator and poll flags
|
|
local function ctrl_init()
|
|
local ctrl = { fdin = nixio.open(CTRL_PATH_IN, O_RDWR_NONBLOCK),
|
|
fdout = nixio.open(CTRL_PATH_OUT, O_RDWR_NONBLOCK),
|
|
events = POLLIN,
|
|
revents = 0 }
|
|
|
|
if ctrl.fdin == nil or ctrl.fdout == nil then
|
|
print('Error. Unable to open the ctrl fifos.')
|
|
print('Exiting...')
|
|
exit(1)
|
|
end
|
|
|
|
-- acquire an exclusive lock on the ctrl fifos or exit
|
|
if not (ctrl.fdin:lock('tlock') and ctrl.fdout:lock('tlock')) then
|
|
print('Error. Detected a lock on one of the ctrl fifos.')
|
|
print('Exiting...')
|
|
exit(1)
|
|
end
|
|
|
|
ctrl.fd = ctrl.fdout -- need this entry for nixio.poll
|
|
ctrl.line = ctrl.fdout:linesource()
|
|
|
|
return ctrl
|
|
end
|
|
|
|
--- Close the spid control fifo's.
|
|
-- @param code ctrl object
|
|
-- @return none
|
|
local function ctrl_close(ctrl)
|
|
ctrl.fdin:close()
|
|
ctrl.fdout:close()
|
|
end
|
|
|
|
--- Send a command to the control fifo.
|
|
-- @param ctrl ctrl object
|
|
-- @param cmd command to send
|
|
-- @return none
|
|
local function send(ctrl, cmd)
|
|
while ctrl.line() do end -- flush the out fifo
|
|
|
|
for i = 1, MAX_TRIES do
|
|
ctrl.fdin:write(cmd .. '\n')
|
|
|
|
local poll, errno, errmsg = nixio.poll({ ctrl }, POLL_TIMEOUT_MS)
|
|
|
|
if poll < 0 then
|
|
print('Error. Poll failed with error message: ' .. errmsg)
|
|
|
|
elseif poll == 0 then
|
|
print('Error. Poll timed out after ' .. POLL_TIMEOUT_MS .. 'ms')
|
|
|
|
elseif poll > 0 then
|
|
reply = ctrl.line()
|
|
|
|
if cmd:sub(1, 1) == 's' then
|
|
if reply == cmd then
|
|
print(reply .. ' .. ok')
|
|
return reply
|
|
else
|
|
print(reply .. ' .. nok .. should be ' .. cmd .. ' instead')
|
|
end
|
|
elseif cmd:sub(1, 2) == reply:sub(1, 2) then
|
|
print(reply .. ' .. ok')
|
|
return reply
|
|
else
|
|
print(reply .. ' .. nok')
|
|
end
|
|
end
|
|
end
|
|
|
|
print(MAX_TRIES .. ' write attempts failed. Exiting ...')
|
|
exit(2)
|
|
end
|
|
|
|
--- Check the sensor board hardware version.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function check_hw_version(ctrl)
|
|
local hw_major, hw_minor = send(ctrl, GET_HW_VERSION):match(GET_HW_VERSION_R)
|
|
|
|
if hw_major ~= flukso.main.hw_major or hw_minor > flukso.main.hw_minor then
|
|
print(string.format('Hardware check (major: %s, minor: %s) .. nok', hw_major, hw_minor))
|
|
if hw_major ~= flukso.main.hw_major then
|
|
print('Error. Major version does not match.')
|
|
end
|
|
|
|
if hw_minor > flukso.main.hw_minor then
|
|
print('Error. Sensor board minor version is not supported by this package.')
|
|
end
|
|
|
|
if HW_CHECK_OVERRIDE then
|
|
print('Overridden. Good luck!')
|
|
else
|
|
print('Use -f to override this check at your own peril.')
|
|
exit(3)
|
|
end
|
|
else
|
|
print(string.format('Hardware check (major: %s, minor: %s) .. ok', hw_major, hw_minor))
|
|
end
|
|
end
|
|
|
|
--- Disable all sensors in the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function disable_all_sensors(ctrl)
|
|
for i = 1, MAX_SENSORS do
|
|
local cmd = string.format(SET_ENABLE, toc(i), 0)
|
|
send(ctrl, cmd)
|
|
end
|
|
end
|
|
|
|
--- Populate the physical (port) to logical (sensor) map on the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function set_phy_to_log(ctrl)
|
|
local phy_to_log = {}
|
|
|
|
for i = 1, MAX_SENSORS do
|
|
if flukso[tostring(i)] ~= nil then
|
|
if flukso[tostring(i)]['class'] == 'analog' and i > MAX_ANALOG_SENSORS then
|
|
print(string.format('Error. Analog sensor %s should be less than or equal to max_analog_sensors (%s)', i, MAX_ANALOG_SENSORS))
|
|
exit(4)
|
|
end
|
|
|
|
local ports = flukso[tostring(i)].port or {}
|
|
|
|
for j = 1, #ports do
|
|
if tonumber(ports[j]) > MAX_SENSORS then
|
|
print(string.format('Error. Port numbering in sensor %s should be less than or equal to max_sensors (%s)', i, MAX_SENSORS))
|
|
exit(5)
|
|
|
|
else
|
|
phy_to_log[toc(tonumber(ports[j]))] = toc(i)
|
|
end
|
|
end
|
|
end
|
|
end
|
|
|
|
-- ports that are not in use are mapped to sensor id 0xff
|
|
for i = 0, MAX_SENSORS - 1 do
|
|
if not phy_to_log[i] then
|
|
phy_to_log[i] = 0xff
|
|
end
|
|
end
|
|
|
|
local cmd = SET_PHY_TO_LOG .. ' ' .. table.concat(phy_to_log, ' ', 0)
|
|
send(ctrl, cmd)
|
|
end
|
|
|
|
--- Populate each sensor's meterconstant on the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function set_meterconst(ctrl)
|
|
for i = 1, MAX_SENSORS do
|
|
local cmd
|
|
|
|
if flukso[tostring(i)] == nil then
|
|
cmd = string.format(SET_METERCONST, toc(i), 0)
|
|
|
|
elseif flukso[tostring(i)]['class'] == 'analog' then
|
|
local voltage = tonumber(flukso[tostring(i)].voltage or "0")
|
|
local current = tonumber(flukso[tostring(i)].current or "0")
|
|
cmd = string.format(SET_METERCONST, toc(i), math.floor(METERCONST_FACTOR * voltage * current))
|
|
|
|
elseif flukso[tostring(i)]['class'] == 'pulse'then
|
|
local meterconst = tonumber(flukso[tostring(i)].constant or "0")
|
|
cmd = string.format(SET_METERCONST, toc(i), meterconst)
|
|
|
|
else
|
|
cmd = string.format(SET_METERCONST, toc(i), 0)
|
|
end
|
|
|
|
if cmd then send(ctrl,cmd) end
|
|
end
|
|
end
|
|
|
|
--- Reset each sensor's counter on the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function reset_counters(ctrl)
|
|
for i = 1, MAX_SENSORS do
|
|
local cmd = string.format(SET_COUNTER, toc(i), 0)
|
|
send(ctrl, cmd)
|
|
end
|
|
|
|
uci:set('flukso', 'main', 'reset_counters', 0)
|
|
uci:commit('flukso')
|
|
end
|
|
|
|
--- Activate the enabled sensors on the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function enable_sensors(ctrl)
|
|
for i = 1, MAX_SENSORS do
|
|
if flukso[tostring(i)] ~= nil and flukso[tostring(i)].enable == '1' then
|
|
cmd = string.format(SET_ENABLE, toc(i), 1)
|
|
send(ctrl, cmd)
|
|
end
|
|
end
|
|
end
|
|
|
|
--- Commit all changes on the sensor board.
|
|
-- @param ctrl ctrl object
|
|
-- @return none
|
|
local function commit(ctrl)
|
|
send(ctrl, COMMIT)
|
|
end
|
|
|
|
|
|
--- Map /sensor/xyz endpoints to the cgi script.
|
|
-- @return none
|
|
local function create_symlinks()
|
|
-- make sure /www/sensor exists
|
|
nixio.fs.mkdirr(API_PATH)
|
|
|
|
-- clean up old symlinks
|
|
for symlink in nixio.fs.dir(API_PATH) do
|
|
nixio.fs.unlink(API_PATH .. symlink)
|
|
end
|
|
|
|
-- generate new symlinks
|
|
for i = 1, MAX_SENSORS do
|
|
if flukso[tostring(i)] ~= nil
|
|
and flukso[tostring(i)].enable == '1'
|
|
and flukso[tostring(i)].id
|
|
and flukso[tostring(i)].class ~= 'uart'
|
|
then
|
|
|
|
local sensor_id = flukso[tostring(i)].id
|
|
|
|
if sensor_id then
|
|
nixio.fs.symlink(CGI_SCRIPT, API_PATH .. sensor_id)
|
|
print(string.format('ln -s %s %s%s .. ok', CGI_SCRIPT, API_PATH, sensor_id))
|
|
end
|
|
end
|
|
end
|
|
end
|
|
|
|
--- Generate a new flukso.service xml file for the avahi-daemon.
|
|
-- @return none
|
|
local function create_avahi_config()
|
|
avahi = { head = {}, body = {}, tail = {} }
|
|
|
|
avahi.head[1] = '<?xml version="1.0" standalone="no"?><!--*-nxml-*-->'
|
|
avahi.head[2] = '<!DOCTYPE service-group SYSTEM "avahi-service.dtd">'
|
|
avahi.head[3] = '<service-group>'
|
|
avahi.head[4] = ' <name replace-wildcards="yes">Flukso RESTful API on %h</name>'
|
|
avahi.head[5] = ' <service>'
|
|
avahi.head[6] = ' <type>_flukso._tcp</type>'
|
|
avahi.head[7] = ' <port>8080</port>'
|
|
|
|
for i = 1, MAX_SENSORS do
|
|
if flukso[tostring(i)] ~= nil
|
|
and flukso[tostring(i)].enable == '1'
|
|
and flukso[tostring(i)].id
|
|
and flukso[tostring(i)].class ~= 'uart'
|
|
then
|
|
|
|
avahi.body[#avahi.body + 1] = string.format(' <txt-record>id%d=%s</txt-record>' , i, flukso[tostring(i)].id)
|
|
end
|
|
end
|
|
|
|
avahi.tail[1] = ' <txt-record>path=/sensor</txt-record>'
|
|
avahi.tail[2] = ' <txt-record>version=1.0</txt-record>'
|
|
avahi.tail[3] = ' </service>'
|
|
avahi.tail[4] = '</service-group>'
|
|
|
|
-- remove the old flukso.service
|
|
nixio.fs.unlink(AVAHI_PATH)
|
|
|
|
-- generate the new one
|
|
fd = nixio.open(AVAHI_PATH, O_RDWR_CREAT)
|
|
print(string.format('generating a new %s', AVAHI_PATH))
|
|
|
|
for i = 1, #avahi.head do
|
|
fd:write(avahi.head[i] .. '\n')
|
|
end
|
|
|
|
for i = 1, #avahi.body do
|
|
fd:write(avahi.body[i] .. '\n')
|
|
end
|
|
|
|
for i = 1, #avahi.tail do
|
|
fd:write(avahi.tail[i] .. '\n')
|
|
end
|
|
end
|
|
|
|
--- POST each sensor's parameters to the /sensor/xyz endpoint
|
|
-- @return none
|
|
local function phone_home()
|
|
local function json_config(i) -- type(i) --> "string"
|
|
local config = {}
|
|
|
|
config["class"] = flukso[i]["class"]
|
|
config["type"] = flukso[i]["type"]
|
|
config["function"] = flukso[i]["function"]
|
|
config["voltage"] = tonumber(flukso[i]["voltage"])
|
|
config["current"] = tonumber(flukso[i]["current"])
|
|
config["constant"] = tonumber(flukso[i]["constant"])
|
|
config["enable"] = tonumber(flukso[i]["enable"])
|
|
|
|
return luci.json.encode{ config = config }
|
|
end
|
|
|
|
local headers = {}
|
|
headers['Content-Type'] = 'application/json'
|
|
headers['X-Version'] = '1.0'
|
|
headers['User-Agent'] = USER_AGENT
|
|
|
|
local options = {}
|
|
options.sndtimeo = 5
|
|
options.rcvtimeo = 5
|
|
|
|
options.tls_context_set_verify = 'peer'
|
|
options.cacert = CACERT
|
|
options.method = 'POST'
|
|
options.headers = headers
|
|
|
|
local http_persist = httpclient.create_persistent()
|
|
|
|
for i = 1, MAX_SENSORS do
|
|
if flukso[tostring(i)] ~= nil and flukso[tostring(i)].id then
|
|
local sensor_id = flukso[tostring(i)].id
|
|
|
|
if i ~= MAX_SENSORS then
|
|
options.headers['Connection'] = 'keep-alive'
|
|
else
|
|
options.headers['Connection'] = 'close'
|
|
end
|
|
|
|
options.body = json_config(tostring(i))
|
|
options.headers['Content-Length'] = tostring(#options.body)
|
|
|
|
local hash = nixio.crypto.hmac('sha1', WAN_KEY)
|
|
hash:update(options.body)
|
|
options.headers['X-Digest'] = hash:final()
|
|
|
|
local url = WAN_BASE_URL .. sensor_id
|
|
local response, code, call_info = http_persist(url, options)
|
|
|
|
local level
|
|
|
|
if code == 200 or code == 204 then
|
|
level = 'info'
|
|
else
|
|
level = 'err'
|
|
end
|
|
|
|
nixio.syslog(level, string.format('%s %s: %s', options.method, url, code))
|
|
|
|
-- if available, send additional error info to the syslog
|
|
if type(call_info) == 'string' then
|
|
nixio.syslog('err', call_info)
|
|
elseif type(call_info) == 'table' then
|
|
local auth_error = call_info.headers['WWW-Authenticate']
|
|
|
|
if auth_error then
|
|
nixio.syslog('err', string.format('WWW-Authenticate: %s', auth_error))
|
|
end
|
|
end
|
|
end
|
|
end
|
|
end
|
|
|
|
-- open the connection to the syslog deamon, specifying our identity
|
|
nixio.openlog('fsync', 'pid')
|
|
|
|
-- sync config to sensor board
|
|
local ctrl = ctrl_init()
|
|
|
|
check_hw_version(ctrl)
|
|
disable_all_sensors(ctrl)
|
|
set_phy_to_log(ctrl)
|
|
set_meterconst(ctrl)
|
|
|
|
if RESET_COUNTERS then
|
|
reset_counters(ctrl)
|
|
end
|
|
|
|
enable_sensors(ctrl)
|
|
commit(ctrl)
|
|
|
|
ctrl_close(ctrl)
|
|
|
|
|
|
-- sync config locally
|
|
create_symlinks()
|
|
create_avahi_config()
|
|
|
|
|
|
-- sync config with the server
|
|
if SYNC_TO_SERVER then
|
|
phone_home()
|
|
end
|
|
|
|
|
|
print(arg[0] .. ' completed successfully. Bye!')
|
|
exit(0)
|