uc: use a formula to calculate METERCONST: METERCONST=0.479*Vrms*Imax (nWh) for 1-phase and METERCONST=0.477*Vrms*Imax (nWh)
This commit is contained in:
parent
933654eb9c
commit
cbd4283d18
|
@ -56,7 +56,7 @@ SENSOR1 = 0123456789abcdef0123456789abcde1
|
|||
SENSOR2 = 0123456789abcdef0123456789abcde2
|
||||
SENSOR3 = 0123456789abcdef0123456789abcde3
|
||||
#
|
||||
CEXTRA = -D DBG=$(DBG) -D TYPE=$(TYPE) -D METERCONST=$(METERCONST) -D 'SENSOR0="$(SENSOR0)"' -D 'SENSOR1="$(SENSOR1)"' -D 'SENSOR2="$(SENSOR2)"' -D 'SENSOR3="$(SENSOR3)"'
|
||||
CEXTRA = -D DBG=$(DBG) -D METERCONST=$(METERCONST) -D 'SENSOR0="$(SENSOR0)"' -D 'SENSOR1="$(SENSOR1)"' -D 'SENSOR2="$(SENSOR2)"' -D 'SENSOR3="$(SENSOR3)"'
|
||||
###############################################################################
|
||||
|
||||
|
||||
|
@ -259,7 +259,7 @@ bin/core.a: $(OBJ)
|
|||
|
||||
# Target: clean project.
|
||||
clean:
|
||||
$(REMOVE) bin/$(TARGET).hex bin/$(TARGET).eep bin/$(TARGET).cof bin/$(TARGET).elf \
|
||||
@$(REMOVE) bin/$(TARGET).hex bin/$(TARGET).eep bin/$(TARGET).cof bin/$(TARGET).elf \
|
||||
bin/$(TARGET).map bin/$(TARGET).sym bin/$(TARGET).lss bin/$(TARGET).c bin/core.a \
|
||||
$(OBJ) $(LST) $(SRC:.c=.s) $(SRC:.c=.d) $(CXXSRC:.cpp=.s) $(CXXSRC:.cpp=.d)
|
||||
|
||||
|
|
116
uc/main.h
116
uc/main.h
|
@ -27,129 +27,25 @@
|
|||
# define SECOND 624 // 625Hz - 1
|
||||
|
||||
#ifndef SENSOR0
|
||||
#define SENSOR0 "0123456789abcdef0123456789abcde0"
|
||||
#error "SENSOR0 not defined"
|
||||
#endif
|
||||
|
||||
#ifndef SENSOR1
|
||||
#define SENSOR1 "0123456789abcdef0123456789abcde1"
|
||||
#error "SENSOR1 not defined"
|
||||
#endif
|
||||
|
||||
#ifndef SENSOR2
|
||||
#define SENSOR2 "0123456789abcdef0123456789abcde2"
|
||||
#error "SENSOR2 not defined"
|
||||
#endif
|
||||
|
||||
#ifndef SENSOR3
|
||||
#define SENSOR3 "0123456789abcdef0123456789abcde3"
|
||||
#error "SENSOR3 not defined"
|
||||
#endif
|
||||
|
||||
#ifndef TYPE
|
||||
#define TYPE 2300501
|
||||
#ifndef METERCONST
|
||||
#error "METERCONST not defined"
|
||||
#endif
|
||||
|
||||
#ifndef METERCONST // @ 625Hz sampling rate
|
||||
#if TYPE == 2200501
|
||||
#define METERCONST 5299
|
||||
#warning "220V - 50A - 1-phase selected. METERCONST set to 5299"
|
||||
|
||||
#elif TYPE == 2200503
|
||||
#define METERCONST 5251
|
||||
#warning "220V - 50A - 3-phase selected. METERCONST set to 5251"
|
||||
|
||||
#elif TYPE == 2300501
|
||||
#define METERCONST 5540
|
||||
#warning "230V - 50A - 1-phase selected. METERCONST set to 5540"
|
||||
|
||||
#elif TYPE == 2300503
|
||||
#define METERCONST 5489
|
||||
#warning "230V - 50A - 3-phase selected. METERCONST set to 5489"
|
||||
|
||||
#elif TYPE == 2400501
|
||||
#define METERCONST 5780
|
||||
#warning "240V - 50A - 1-phase selected. METERCONST set to 5780"
|
||||
|
||||
#elif TYPE == 2400503
|
||||
#define METERCONST 5727
|
||||
#warning "240V - 50A - 3-phase selected. METERCONST set to 5727"
|
||||
|
||||
|
||||
#elif TYPE == 2201001
|
||||
#define METERCONST 10598
|
||||
#warning "220V - 100A - 1-phase selected. METERCONST set to 10598"
|
||||
|
||||
#elif TYPE == 2201003
|
||||
#define METERCONST 10502
|
||||
#warning "220V - 100A - 3-phase selected. METERCONST set to 10502"
|
||||
|
||||
#elif TYPE == 2301001
|
||||
#define METERCONST 11080
|
||||
#warning "230V - 100A - 1-phase selected. METERCONST set to 11080"
|
||||
|
||||
#elif TYPE == 2301003
|
||||
#define METERCONST 10978
|
||||
#warning "230V - 100A - 3-phase selected. METERCONST set to 10978"
|
||||
|
||||
#elif TYPE == 2401001
|
||||
#define METERCONST 11560
|
||||
#warning "240V - 100A - 1-phase selected. METERCONST set to 11560"
|
||||
|
||||
#elif TYPE == 2401003
|
||||
#define METERCONST 11454
|
||||
#warning "240V - 100A - 3-phase selected. METERCONST set to 11454"
|
||||
|
||||
|
||||
#elif TYPE == 2202501
|
||||
#define METERCONST 26495
|
||||
#warning "220V - 250A - 1-phase selected. METERCONST set to 26495"
|
||||
|
||||
#elif TYPE == 2202503
|
||||
#define METERCONST 26255
|
||||
#warning "220V - 250A - 3-phase selected. METERCONST set to 26255"
|
||||
|
||||
#elif TYPE == 2302501
|
||||
#define METERCONST 27700
|
||||
#warning "230V - 250A - 1-phase selected. METERCONST set to 27700"
|
||||
|
||||
#elif TYPE == 2302503
|
||||
#define METERCONST 27445
|
||||
#warning "230V - 250A - 3-phase selected. METERCONST set to 27445"
|
||||
|
||||
#elif TYPE == 2402501
|
||||
#define METERCONST 28900
|
||||
#warning "240V - 250A - 1-phase selected. METERCONST set to 28900"
|
||||
|
||||
#elif TYPE == 2402503
|
||||
#define METERCONST 28635
|
||||
#warning "240V - 250A - 3-phase selected. METERCONST set to 28635"
|
||||
|
||||
|
||||
#elif TYPE == 2205001
|
||||
#define METERCONST 52990
|
||||
#warning "220V - 500A - 1-phase selected. METERCONST set to 52990"
|
||||
|
||||
#elif TYPE == 2205003
|
||||
#define METERCONST 52510
|
||||
#warning "220V - 500A - 3-phase selected. METERCONST set to 52510"
|
||||
|
||||
#elif TYPE == 2305001
|
||||
#define METERCONST 55400
|
||||
#warning "230V - 500A - 1-phase selected. METERCONST set to 55400"
|
||||
|
||||
#elif TYPE == 2305003
|
||||
#define METERCONST 54890
|
||||
#warning "230V - 500A - 3-phase selected. METERCONST set to 54890"
|
||||
|
||||
#elif TYPE == 2405001
|
||||
#define METERCONST 57800
|
||||
#warning "240V - 500A - 1-phase selected. METERCONST set to 57800"
|
||||
|
||||
#elif TYPE == 2405003
|
||||
#define METERCONST 57270
|
||||
#warning "240V - 500A - 3-phase selected. METERCONST set to 57270"
|
||||
#endif
|
||||
#endif
|
||||
|
||||
//#define POWERCONST (METERCONST*1758)/1000 // in mW
|
||||
|
||||
#define START 0
|
||||
#define END3 0xffffffff
|
||||
#define END2 0xeeeeeeee
|
||||
|
|
Loading…