uc: include METERCONST and MUXN as config options in Makefile
This commit is contained in:
parent
2b769d5556
commit
b6e98cd734
|
@ -86,13 +86,15 @@ F_CPU = 1000000
|
|||
# make TYPE= xxxx SENSOR0=yyyy ...
|
||||
#
|
||||
TYPE = 2301
|
||||
METERCONST = 7091
|
||||
MUXN = 0
|
||||
#
|
||||
SENSOR0 = 0123456789abcdef0123456789abcde0
|
||||
SENSOR1 = 0123456789abcdef0123456789abcde1
|
||||
SENSOR2 = 0123456789abcdef0123456789abcde2
|
||||
SENSOR3 = 0123456789abcdef0123456789abcde3
|
||||
#
|
||||
CEXTRA = -D TYPE=$(TYPE) -D 'SENSOR0="$(SENSOR0)"' -D 'SENSOR1="$(SENSOR1)"' -D 'SENSOR2="$(SENSOR2)"' -D 'SENSOR3="$(SENSOR3)"'
|
||||
CEXTRA = -D TYPE=$(TYPE) -D METERCONST=$(METERCONST) -D MUXN=$(MUXN) -D 'SENSOR0="$(SENSOR0)"' -D 'SENSOR1="$(SENSOR1)"' -D 'SENSOR2="$(SENSOR2)"' -D 'SENSOR3="$(SENSOR3)"'
|
||||
#####################################################################################
|
||||
|
||||
#####################################################################################
|
||||
|
|
15
uc/main.h
15
uc/main.h
|
@ -40,36 +40,37 @@
|
|||
#define TYPE 2301
|
||||
#endif
|
||||
|
||||
|
||||
#if TYPE == 2201 // 220V - 1-phase @ 488.28Hz sampling rate
|
||||
#ifndef METERCONST
|
||||
#if TYPE == 2201 // 220V - 1-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 6783
|
||||
#define MUXN 0
|
||||
#warning "220V - 1-phase selected. METERCONST set to 6783"
|
||||
|
||||
#elif TYPE == 2203 // 220V - 3-phase @ 488.28Hz sampling rate
|
||||
#elif TYPE == 2203 // 220V - 3-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 6721
|
||||
#define MUXN 1
|
||||
#warning "220V - 3-phase selected. METERCONST set to 6721"
|
||||
|
||||
#elif TYPE == 2301 // 230V - 1-phase @ 488.28Hz sampling rate
|
||||
#elif TYPE == 2301 // 230V - 1-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 7091
|
||||
#define MUXN 0
|
||||
#warning "230V - 1-phase selected. METERCONST set to 7091"
|
||||
|
||||
#elif TYPE == 2303 // 230V - 3-phase @ 488.28Hz sampling rate
|
||||
#elif TYPE == 2303 // 230V - 3-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 7026
|
||||
#define MUXN 1
|
||||
#warning "230V - 3-phase selected. METERCONST set to 7026"
|
||||
|
||||
#elif TYPE == 2401 // 240V - 1-phase @ 488.28Hz sampling rate
|
||||
#elif TYPE == 2401 // 240V - 1-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 7399
|
||||
#define MUXN 0
|
||||
#warning "240V - 1-phase selected. METERCONST set to 7399"
|
||||
|
||||
#elif TYPE == 2403 // 240V - 3-phase @ 488.28Hz sampling rate
|
||||
#elif TYPE == 2403 // 240V - 3-phase @ 488.28Hz sampling rate
|
||||
#define METERCONST 7331
|
||||
#define MUXN 1
|
||||
#warning "240V - 3-phase selected. METERCONST set to 7331"
|
||||
#endif
|
||||