[fsync] enable/disable cmd works on sensors, not on ports
This commit is contained in:
parent
035bc2d4fe
commit
55ecdd3451
|
@ -144,9 +144,7 @@ end
|
|||
local phy_to_log = {}
|
||||
|
||||
for i = 1, MAX_SENSORS do
|
||||
local set = { analog = true, pulse = true }
|
||||
|
||||
if flukso[tostring(i)] ~= nil and set[flukso[tostring(i)]['type']] then
|
||||
if flukso[tostring(i)] ~= nil then
|
||||
local ports = flukso[tostring(i)].port or {}
|
||||
|
||||
for j = 1, #ports do
|
||||
|
@ -160,6 +158,7 @@ for i = 1, MAX_SENSORS do
|
|||
end
|
||||
end
|
||||
|
||||
-- ports that are not in use are mapped to sensor id 0xff
|
||||
for i = 0, MAX_SENSORS - 1 do
|
||||
if not phy_to_log[i] then
|
||||
phy_to_log[i] = 0xff
|
||||
|
@ -202,16 +201,12 @@ if flukso.main.reset_counters == '1' then
|
|||
uci:commit('flukso')
|
||||
end
|
||||
|
||||
-- enable configured ports
|
||||
-- enable configured sensors
|
||||
for i = 1, MAX_SENSORS do
|
||||
if flukso[tostring(i)] ~= nil and flukso[tostring(i)].enable == '1' then
|
||||
local ports = flukso[tostring(i)].port or {}
|
||||
|
||||
for j = 1, #ports do
|
||||
cmd = string.format(SET_ENABLE, toc(tonumber(ports[j])), 1)
|
||||
cmd = string.format(SET_ENABLE, toc(i), 1)
|
||||
send(ctrl, cmd)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- clean up
|
||||
|
|
Loading…