change control type and field weakening

This commit is contained in:
interfisch 2019-12-03 22:21:47 +01:00
parent 5a73c8722f
commit 5de1169cef
1 changed files with 2 additions and 2 deletions

View File

@ -142,10 +142,10 @@
// ############################### MOTOR CONTROL (overwrite) #########################
#define CTRL_TYP_SEL 2 // [-] Control type selection: 0 = Commutation , 1 = Sinusoidal, 2 = FOC Field Oriented Control (default)
#define CTRL_TYP_SEL 1 // [-] Control type selection: 0 = Commutation , 1 = Sinusoidal, 2 = FOC Field Oriented Control (default)
#define CTRL_MOD_REQ 1 // [-] Control mode request: 0 = Open mode, 1 = VOLTAGE mode (default), 2 = SPEED mode, 3 = TORQUE mode. Note: SPEED and TORQUE modes are only available for FOC!
#define DIAG_ENA 1 // [-] Motor Diagnostics enable flag: 0 = Disabled, 1 = Enabled (default)
#define FIELD_WEAK_ENA 0 // [-] Field Weakening enable flag: 0 = Disabled (default), 1 = Enabled
#define FIELD_WEAK_ENA 1 // [-] Field Weakening enable flag: 0 = Disabled (default), 1 = Enabled
#define I_MOT_MAX (15 * A2BIT_CONV) << 4 // [A] Maximum motor current limit (Change only the first number, the rest is needed for fixed-point conversion, fixdt(1,16,4))
#define I_DC_MAX (17 * A2BIT_CONV) // [A] Maximum DC Link current limit (This is the final current protection. Above this value, current chopping is applied. To avoid this make sure that I_DC_MAX = I_MOT_MAX + 2A )
#define N_MOT_MAX 800 << 4 // [rpm] Maximum motor speed (change only the first number, the rest is needed for fixed-point conversion, fixdt(1,16,4))